The flowable injection technique lets you build anterior composite restorations that match an approved wax-up, usually without removing tooth structure. A clear silicone index carries the planned shape to the mouth, and a highly filled flowable composite is injected into it and cured through it. This article covers case selection, how to design and sequence the index, the chairside protocol with bonding and curing parameters, and the errors that most often spoil the result.
What the flowable injection technique is
The technique is best described as indirect-direct: the shape is designed indirectly on a cast or in software, and the restoration is made directly in the mouth. Geštakovski, who has published a detailed clinical protocol, describes it as a way to translate a diagnostic wax-up accurately and predictably into composite restorations without the need for tooth preparation (Geštakovski 2019). A resin composite injection technique was described earlier by Terry and Powers (Terry and Powers 2014).
It is worth separating it from the "index technique" of Ammannato and colleagues, in which paste composite is loaded into a transparent index and stamped onto the tooth (Ammannato et al. 2015). Both are additive and wax-up driven. With injection, the index is seated first and stays still; the material flows in through a port.
The materials make the difference. Highly filled "injectable" composites are not the low-filled flowables used as liners. In a laboratory comparison, two injectable composites showed lower wear and higher flexural strength than both a conventional flowable and a paste composite (Rajabi et al. 2024). G-ænial Universal Injectable, one of the products tested, contains about 46 vol% inorganic filler and is supplied in 16 shades (GC instructions for use). Dr Hajtó uses the same material in his own protocols as a purely light-cured luting composite for veneers, inlays and tabletops.
Case selection for anterior injection
The published anterior cases cover a consistent range: diastema closure, lengthening of teeth with too little display, reshaping canines to restore guidance in lateral excursion (Geštakovski 2019), and copying a natural contralateral tooth to reshape a lateral incisor (Geštakovski 2021). The common factor is an additive change on sound enamel.
| Case | Suitability | What to watch |
|---|---|---|
| Diastemas, short or narrow teeth | well suited | emergence and papilla support at the gingival margin |
| Reshaping single teeth (e.g. 12 or 22) | well suited | shade and translucency match to the contralateral tooth |
| Canine build-ups for guidance (13, 23) | good, with limits | wear of the guiding surface, repairs |
| Worn anterior teeth with bite raising | possible | functional planning, posterior support |
| Proximal reconstruction, contact areas | limited | silicone less accurate proximally |
Two limits deserve a clear conversation with the patient. Shade is harder than shape: even in a simple reshaping case, the high translucency of the incisal edges made shade selection challenging (Geštakovski 2021). And composite under function wears. Dr Hajtó's experience with direct canine build-ups is that abrasion resistance is the weak point and repairs or replacements are often needed.
Planning: wax-up, mock-up and function
Because the index copies the wax-up exactly, design errors are copied too. Spend the time here.
In the 2019 case, the wax-up was made while simulating functional movements on an articulator, and a mock-up was checked in the mouth before the index was produced (Geštakovski 2019). For form, the rules from ceramic work apply: labial ridges influence how wide a tooth looks, and natural teeth are always slightly asymmetrical.
Function sets the boundaries. Dr Hajtó plans no dynamic contacts on the maxillary lateral incisors and avoids canine guidance that is too steep, since guidance above about 60° can lead to tapping. When a canine is built up in composite he shapes the guiding surface concave, keeps a minimal centric contact that holds shimstock, and sets the steepness so that the patient finds it comfortable. More background is in the article on canine guidance as an occlusion concept.
For the mock-up itself, Dr Hajtó uses a direct mock-up without preparation: flowable composite is applied through a matrix, on etched or unetched enamel. It is quick and convincing and allows a test phase, but it gives only an approximate impression without fine detail. The steps from wax-up to matrix are covered in diagnostic wax-up and mock-up.
Veneer Preparation course
Preparation, material choice and bonding of veneers, hands-on and taught in English.
View the courseDesigning the clear silicone index
Dr Hajtó's requirements for a silicone matrix translate directly to the injection index:
- extended 2 to 3 teeth beyond the treatment area
- interdental spaces fully moulded
- no bubbles
- crystal-clear silicone, such as Exaclear (GC), Matrix Flow (Anaxdent), Esthetic Gum (Picodent) or Memosil (Kulzer)
- a smooth tray
Products differ visibly in how many gas bubbles they trap, and every bubble in the index becomes a defect on the restoration or a shadow during curing.
Ports and sequencing
Each tooth gets a port through which the dispensing tip reaches the cavity between tooth and index. In a model study, veneers injected through clear silicone matrices with such holes did not differ significantly from the wax-up, and that held when the first teeth were restored with a separate matrix made from an "every other tooth" wax-up. Matrices cut for single teeth and filled with preheated paste composite were the least accurate (Kouri et al. 2023).
Sequencing matters because neighbouring restorations otherwise fuse. Restoring alternate teeth first (for example 11, 13 and 22) and then the remaining teeth leaves each proximal surface free while it is being moulded. Geštakovski's double-model approach, where teeth are restored individually, improved index stability and interproximal precision and prevented material flowing onto adjacent teeth (Geštakovski and Helinger Geštakovski 2026). At the gingival margin the index can be trimmed back; the 2019 case also used retraction cords (Geštakovski 2019).
How accurate is silicone?
In vitro, a 6 mm clear silicone guide was the most accurate option at the incisal third (RMS deviation 0.070 mm), while rigid printed guides with matrix slots performed significantly better on proximal surfaces. Planned veneer thickness between 0.1 and 0.7 mm had no significant effect on accuracy (Luo et al. 2026). This matches the known weaknesses of moulding techniques: index deformation, time-consuming removal of excess in the contact areas and limited precision of fine anatomy (Dietschi and Saratti 2020).
Flowable injection technique protocol, step by step
The steps below combine the published protocol, the manufacturer's instructions and Dr Hajtó's adhesive routine. Curing values refer to G-ænial Universal Injectable; for other materials follow their instructions.
- Choose the shade before isolation and etching, with particular care where the incisal edge is highly translucent.
- Isolate. A saliva-free, dry, accessible field is the precondition for bonding. The manufacturer recommends rubber dam (GC instructions for use); see rubber dam isolation.
- Protect the neighbours. Cover teeth not treated in this round with PTFE (Teflon) tape.
- Etch the enamel with phosphoric acid, in Dr Hajtó's protocol for 15 to 20 seconds, then rinse thoroughly and dry carefully. In vitro, etching before a universal adhesive significantly raised enamel bond strength of injectable composites; in self-etch mode 70 % of failures were adhesive, after etching none were (Chaves et al. 2026).
- Apply and cure the adhesive according to its instructions; the composite's manufacturer specifies a light-cured bonding system.
- Seat the index fully and without tension, check seating on the untreated teeth and hold it steady.
- Purge the tip. With the tip pointing up, advance the plunger until material reaches the opening, so no air is injected.
- Inject. Bring the tip through the port close to the tooth surface and fill slowly until material appears at the margins. Release the pressure and withdraw the tip perpendicular to the surface so the material separates cleanly.
- Light-cure. The manufacturer specifies 10 seconds with a high-power LED above 1,200 mW/cm² or 20 seconds with a unit above 700 mW/cm², with a depth of cure of 2.5 mm for shades such as A1, A2, A3, B1, B2, JE and AE, 2.0 mm for others including BW and the opaque AO1 and AO2, and 1.5 mm for AO3. The manufacturer asks for the light guide to be kept as close as possible to the surface and for curing in layers within these depths; bear in mind that the silicone index adds distance between light and composite.
- Remove excess at the cervical and proximal margins and take off the PTFE tape.
- Repeat for the remaining teeth.
- Finish and check contour, polish, and static and dynamic occlusion.
The anterior course page lists four ways of working with the injected material, each practised on a separate veneer: monochromatic, cut-back, layering and colour blending. Which one fits depends on how much translucency and characterisation the case needs.
Errors that spoil the result
- Bubbles come from an unpurged tip, a bubbly index or injecting too fast.
- A deformed index gives distorted contours; make it long enough, on a smooth tray, and hold it steadily.
- Material on adjacent teeth follows simultaneous injection of neighbours; isolate with PTFE or work alternately.
- Undercuring: the manufacturer warns that low light intensity can cause insufficient curing or discolouration.
- Contamination of etched enamel with saliva or crevicular fluid compromises the bond.
How long do injected restorations last?
Long-term data specific to the technique are still limited to case reports. Geštakovski found no soft-tissue inflammation or significant wear after 24 months and fitted a protective night splint (Geštakovski 2019). A case restoring vertical dimension with injected composite remained functional after five years but needed periodic maintenance polishing (Clavijo et al. 2026). For worn dentitions in general, a systematic review found more failures with direct composite than with indirect ceramic, while noting that direct methods are the minimally invasive option (Alani et al. 2025). Plan for recalls, polishing and the occasional repair.
Summary
Injection is a reliable way to put an approved wax-up into the mouth when the case is additive, the index is clear and bubble-free, the field is dry and the bonding protocol is clean. If a case also involves closing spaces, see diastema closure with composite; for posterior teeth, read injectable composite tabletops. Index fabrication, rubber dam isolation and injection, with four veneers in different variants of the technique, are covered in the two-day Flowable Injection Anteriors hands-on course, taught in English by David Geštakovski.
Frequently asked questions
What is the flowable injection technique?
It is an additive, indirect-direct method for composite restorations. The planned shape is made as a wax-up, a clear silicone index is taken from it, and a highly filled flowable composite is injected through a port in the index onto the bonded tooth and light-cured. The result reproduces the wax-up closely, usually without tooth preparation, and can be repaired or added to later.
Which composite is used for injection moulding?
Highly filled flowable composites designed for restorative use, such as G-ænial Universal Injectable, are the usual choice. In laboratory tests, injectable composites showed lower wear and higher flexural strength than a conventional flowable and a paste composite. Low-filled flowables made for lining are not designed for visible, load-bearing anterior surfaces. Always follow the product's own indications and curing instructions.
Do the teeth need to be prepared?
Usually not. The technique is designed to be purely additive, so enamel is cleaned, etched with phosphoric acid and bonded rather than reduced. Old restorations, caries or defects are dealt with according to the findings before injection. Where a planned contour would otherwise be over-bulked, the wax-up should be reconsidered first, because the index will reproduce exactly what was designed.
Can you treat all anterior teeth at once?
You can inject several teeth with one index, but adjacent restorations then tend to fuse and contacts need more finishing. Restoring alternate teeth first, with neighbours protected by PTFE tape, and then completing the remaining teeth gives cleaner proximal surfaces. In a model study, neither the single-matrix nor the alternate-tooth approach differed significantly from the wax-up.
How long do injected composite veneers last?
Published follow-ups are mostly case reports of two to five years, in which restorations stayed functional but needed maintenance polishing. Reviews of direct composite in worn dentitions show more failures than with indirect ceramic, offset by minimal invasiveness and easy repair. Regular recalls, polishing, and a night splint where parafunction is present are part of a realistic plan.